Calibration Kit: Individual Calibration Kit Vial. Standards for particle sizes ≤ 25 µm
061F
Calibration Kit: Individual Calibration Kit Vial. Standards for particle sizes ≤ 25 µm
- Any of the vials included in Calibration Kit: PSS Accusizer™ LE400 Sensors-All Modes (MML 061B) may be purchased individually.
- MML recommends purchasing additional vials together with (MML 061B), costs to manufacture the spares is substantially lower at that time.
Category: Uncategorized
Related products
-
PQ Check Standard, USP Count Reference Standard Surrogate
Select options This product has multiple variants. The options may be chosen on the product pagePQ Check Standard, USP Count Reference Standard Surrogate
061UI-125 & 061UI-250 & 061UI-500 &061UI-1000
PQ Check Standard, USP Count Reference Standard Surrogate
- Designed specifically to mimic the USP Count Reference Standard (USP CRS) used during annual calibrations of Light Obscuration (LO) particle counters running USP <788> sub-visible particle count tests on parenteral preparations, this standard is used to verify the performance of an LO instrument performing this test.
- While it cannot be used in place of the USP CRS, this product should be used as a PQ Check in between annual calibrations to ensure the LO instrument is accurately counting particles in parenteral products. By running this standard weekly or bi-weekly, any out-of-specification (OOS) results can quickly be investigated and the instrument making the measurement can easily be ruled out (or confirmed) as the root cause of the OOS result.
-
- Standard material: NIST traceable size Polystyrene latex (PSL) spheres.
- Nominal size and concentration of standard particles:
- 15 µm PSL – 3,750 particles/mL
- Product batch will be ± 10% of the nominal concentration; individual standard bottles will be certified ± 15% of the mean concentration and particle sizes are certified ± 5% of the standard size (± uncertainty)
- The Certificate of Analysis includes actual concentration testing data and mean size.
SKU: N/A Category: Uncategorized -
Flow Imaging: Focus Beads
Select options This product has multiple variants. The options may be chosen on the product pageFlow Imaging: Focus Beads
600-FA Flow Imaging: 2X/4X Focus Beads – 50 µm
Autofocus Bead Standard for Flow Imaging 2X/4X Objectives
- Designed for use with Flow Imaging Autofocus function for 2X and 4X objectives
- Volume: 500 mL
- Each unit will nominally contain 1 sizes of Polystyrene Latex (PSL) spheres:
- Approximately 3,500 particles/mL of 50 µm PSL
- Particles are suspended in a proprietary solution containing a viscous agent to aid in proper flow through the instrument.
- Product batch will be ± 10% of the nominal concentration; individual standard bottles will be certified ± 15% of the mean concentration and particle sizes are certified ± 5% of the standard size (± uncertainty)
- The Certificate of Analysis includes actual concentration testing data and mean size.
600-FB0040 Flow Imaging: 10X/20X Focus Beads – 25 µm
Autofocus Bead Standard for Flow Imaging 10X/20X Objectives
- Designed for use with Flow Imaging Autofocus function for 10X and 20X objectives
- Volume: 40 mL
- Each unit will nominally contain 1 sizes of Polystyrene Latex (PSL) spheres:
- Approximately 65,000 particles/mL of 25 µm PSL
- Particles are suspended in a proprietary solution containing a viscous agent to aid in proper flow through the instrument
- Product batch will be ± 10% of the nominal concentration; individual standard bottles will be certified ± 22% of the mean concentration and particle sizes are certified ± 5% of the standard size (± uncertainty)
- The Certificate of Analysis includes actual concentration testing data and mean size.
600-FB0250 Flow Imaging: 10X/20X Focus Beads – 25 µm
Autofocus Bead Standard for Flow Imaging 10X/20X Objectives
- Designed for use with Flow Imaging Autofocus function for 10X and 20X objectives
- Volume: 250 mL
- Each unit will nominally contain 1 sizes of Polystyrene Latex (PSL) spheres:
- Approximately 65,000 particles/mL of 25 µm PSL
- Particles are suspended in a proprietary solution containing a viscous agent to aid in proper flow through the instrument
- Product batch will be ± 10% of the nominal concentration; individual standard bottles will be certified ± 22% of the mean concentration and particle sizes are certified ± 5% of the standard size (± uncertainty)
- The Certificate of Analysis includes actual concentration testing data and mean size.
600-FC PQ Check Standard, Flow Imaging 0.4, 0.8, 2 µm Particle Count and Size Standard
PQ Check Standard, Flow Imaging 0.4, 0.8, 2 µm Particle Count and Size Standard
- Volume: 125 mL
- Standard material: NIST traceable size Polystyrene latex (PSL) spheres
- Nominal sizes and concentrations of standard particles:
- 0.4 µm PSL – 1,200,000 particles/mL
- 0.8 µm PSL – 800,000 particles/mL
- 2 µm PSL – 400,000 particles/mL
- Product batch will be ± 10% of the nominal concentration; individual standard bottles will be certified ± 22% of the mean concentration and particle sizes are certified ± 5% of the standard size (± uncertainty)
- The Certificate of Analysis includes actual concentration testing data and mean size.
SKU: N/A Category: Uncategorized -
Bi-Mix: 10 µm & 25 µm
-
PQ Check Standard, 25μm for PSS SIS Config